Garantía de 3 años: todos nuestros productos se adaptan al nuevo material enumerado UL, nunca adaptamos el material usado.
Idioma
NTL-FC152-EMC,NTL-FCF152-EMC
Características
Descripción del Producto

Nuestros productos se utilizan ampliamente en paneles de control, cajas de conexiones, cajas de distribución de energía, equipos de automatización, dispositivos electrónicos y de potencia, máquinas de soldar, embalajes, etc. Color normal: RAL 7035, RAL 7032 (el cliente puede fabricar otros colores)

Datos técnicos

NTL-FCF152-EMC

Axial fan, ball bearing

service life L10 at +40℃ (+104℉): min. 37,000h fan body aluminium, rotor metal

Connection

2 stranded wires, 300mm

Enclosure cut-out

125×125mm+1 mm

Mounting frame

4 built-in ratchet braces for mounting (6 notches for wall thickness 1-4mm).

additional use of screws possible if needed.

Filter mat

G4 acc. to DIN EN 779, filtering degree 94%

Filter material

new ABS material confirm to RoHS, fireproof or not fireproof can be choose

Operating/Storage temperature

-25 to +65℃ (-13 to +149℉) / -40 to +70℃ (-40 to +158℉)

Operating/Storage humidity

max. 90% RH (non-condensing)

Protection type/Protection class

IP54 / I (earthed)

Function

with EMC function


Opciones de montaje

Art.No.

Power
supply

Fan size
(mm)

Air flow rate
(free blow)
(m3/h)

Air flow rate
(with mat)
(m3/h)

Power
consumption
(W)

Current
consumption
(A)

Noise
level
(dBA)

FC152-EMC

-

without fan

-

-

-

-

-

FCF152-EMC-230A-C

230VAC

120×120×25

96/112

65

16

0.08

39/42

FCF152-EMC-230B-C

230VAC

120×120×38

138/162

100

21/18

0.12

43/48

FCF152-EMC-115A-C

115VAC

120×120×25

96/112

65

16

0.16

39/42

FCF152-EMC-115B-C

115VAC

120×120×38

138/162

100

21/18

0.22/0.18

43/48

FCF152-EMC-D-C

120&230VAC

120×120×38

138/162

100

19/15

0.18/0.12

43/48

FCF152-EMC-400-C

400VAC

120×120×38

138/162

100

21/18

0.09/0.07

43/48

FCF152-EMC-12-C

12VDC

120×120×38

180

120

7.2

0.6

48

FCF152-EMC-24-C

24VDC

120×120×38

180

120

9.6

0.4

48

FCF152-EMC-48-C

48VDC

120×120×38

180

120

9.6

0.2

48

Normally is airflow direction"Out", if you need airflow direction "In", when place order, please advice.